Item
|
JYPM-50-US
|
JYPM-84-US
|
JYPM-100-US
|
JYPM-125-US
|
JYPM-150-US
|
|---|---|---|---|---|---|
|
Applicable wavelength range
|
colspan="5"
|
200-1100nm
|
|||
|
Time
|
colspan="5"
|
0.2ms
|
|||
|
Integral sphere coating
|
colspan="5"
|
PTFE
|
|||
|
Integral sphere diameter
|
50mm
|
84mm
|
100mm
|
125mm
|
150mm
|
|
Detection aperture
|
13mm
|
25.4mm
|
25.4mm
|
25.4mm
|
25.4mm
|
|
Low power laser
|
1nw-0.01w
|
1nw-0.01w
|
1nw-0.01w
|
1nw-0.01w
|
1nw-0.01w
|
|
Medium power laser
|
100nw-1w
|
100nw-1w
|
100nw-1w
|
100nw-1w
|
100nw-1w
|
|
high power laser
|
10mw-100w
|
10mw-100w
|
10mw-100w
|
10mw-100w
|
10mw-100w
|
|
Uncertainty
|
colspan="5"
|
±5%
|
|||
|
Linearity
|
colspan="5"
|
±0.5%
|
|||
|
uniformity
|
colspan="5"
|
±2%
|
|||
|
Power probe traceability calibration
|
colspan="5"
|
NIST
|
|||
|
communication interface
|
colspan="5"
|
USB2.0
|
|||
|
operation temperature
|
colspan="5"
|
5℃-50℃
|
|||
|
relative humidity
|
colspan="5"
|
<70%RH
|
|
Item
|
JYPM-50-VS
|
JYPM-84-VS
|
JYPM-100-VS
|
JYPM-125-VS
|
JYPM-150-VS
|
|---|---|---|---|---|---|
|
Applicable wavelength range
|
colspan="5"
|
380-1100nm
|
|||
|
Time
|
colspan="5"
|
0.2ms
|
|||
|
Integral sphere coating
|
colspan="5"
|
PTFE
|
|||
|
Integral sphere diameter
|
50mm
|
84mm
|
100mm
|
125mm
|
150mm
|
|
Detection aperture
|
13mm
|
25.4mm
|
25.4mm
|
25.4mm
|
25.4mm
|
|
Low power laser
|
1nw-0.01w
|
1nw-0.01w
|
1nw-0.01w
|
1nw-0.01w
|
1nw-0.01w
|
|
Medium power laser
|
100nw-1w
|
100nw-1w
|
100nw-1w
|
100nw-1w
|
100nw-1w
|
|
high power laser
|
10mw-100w
|
10mw-100w
|
10mw-100w
|
10mw-100w
|
10mw-100w
|
|
Uncertainty
|
colspan="5"
|
±5%
|
|||
|
Linearity
|
colspan="5"
|
±0.5%
|
|||
|
uniformity
|
colspan="5"
|
±2%
|
|||
|
Power probe traceability calibration
|
colspan="5"
|
NIST
|
|||
|
communication interface
|
colspan="5"
|
USB2.0
|
|||
|
operation temperature
|
colspan="5"
|
5℃-50℃
|
|||
|
relative humidity
|
colspan="5"
|
<70%RH
|
|
Item
|
JYPM-50-IS
|
JYPM-84-IS
|
JYPM-100-IS
|
JYPM-125-IS
|
JYPM-150-IS
|
|---|---|---|---|---|---|
|
Applicable wavelength range
|
colspan="5"
|
800-1650nm
|
|||
|
Time
|
colspan="5"
|
0.2ms
|
|||
|
Integral sphere coating
|
colspan="5"
|
PTFE
|
|||
|
Integral sphere diameter
|
50mm
|
84mm
|
100mm
|
125mm
|
150mm
|
|
Detection aperture
|
13mm
|
25.4mm
|
25.4mm
|
25.4mm
|
25.4mm
|
|
Low power laser
|
1nw-0.01w
|
1nw-0.01w
|
1nw-0.01w
|
1nw-0.01w
|
1nw-0.01w
|
|
Medium power laser
|
100nw-1w
|
100nw-1w
|
100nw-1w
|
100nw-1w
|
100nw-1w
|
|
high power laser
|
10mw-100w
|
10mw-100w
|
10mw-100w
|
10mw-100w
|
10mw-100w
|
|
Uncertainty
|
colspan="5"
|
±5%
|
|||
|
Linearity
|
colspan="5"
|
±0.5%
|
|||
|
uniformity
|
colspan="5"
|
±2%
|
|||
|
Power probe traceability calibration
|
colspan="5"
|
NIST
|
|||
|
communication interface
|
colspan="5"
|
USB2.0
|
|||
|
operation temperature
|
colspan="5"
|
5℃-50℃
|
|||
|
relative humidity
|
colspan="5"
|
<70%RH
|
|
Item
|
|---|
|
integrating sphere
|
|
Power meter
|
|
optical fiber
|
|
Analysis and testing software
|
|
Detector front-end attenuator
|
|
Item
|
|---|
|
Detector front-end attenuator
|