Product Introduction
The Jingyi Target Board R90 is a large-size diffuse reflection standard target specifically designed for the 940nm near-infrared band, with a target surface size of 5000×3000mm. The product uses a honeycomb aluminum plate as the substrate, and the surface is coated with a high-reflectivity diffuse reflection layer. The reflectance is stably maintained at 90%, the reflection accuracy is controlled within ±1%, and the surface uniformity is better than 99%. It is an ideal standard device for the calibration and performance testing of large field-of-view and long-distance optical systems.
Product Advantages
Extra-large target surface: The target surface size reaches 5000×3000mm, covering large field-of-view and long-distance calibration scenarios, reducing splicing errors;
High reflection accuracy: Accuracy ±1%, reflectance values are traceable, calibration results are accurate and reliable;
Ultra-high uniformity: Uniformity >99%, consistent reflection across the entire target surface, removing spatial response errors;
Optical-grade flatness: Flatness <1mm meets the requirement for surface flatness in high-precision optical measurements;
Honeycomb aluminum plate substrate: 20mm thick, honeycomb structure offers high rigidity, lightweight, deformation resistance, and long-term stability;
Durable diffuse reflection coating: Coating thickness >0.2mm, wear-resistant and washable, long service life, low maintenance cost;
Wavelength-specific design: Optimized for 940nm near-infrared band, excellent reflection performance, matching mainstream infrared sensors;
Customizable specifications: Supports customization and can be flexibly adjusted according to the customer’s target field and equipment size.
Applications
LiDAR calibration and ranging accuracy testing — Large target surface meets vehicle/robot LiDAR long-distance calibration needs;
940nm infrared/near-infrared camera radiometric calibration — Used for camera response, dark noise, and uniformity calibration;
Autonomous driving multi-sensor fusion calibration — Radar and camera joint calibration scenarios for standardization;
Machine vision large field-of-view system calibration — Industrial wide-field inspection and wide-format imaging equipment calibration;
3D scanning/structured light system accuracy verification — Standard reflection reference for large-space 3D reconstruction devices;
Infrared imaging and remote sensing optical system laboratory testing — Optical performance verification for research institutes and testing agencies;
Optical communication and laser equipment performance testing — Reference target for 940nm wavelength laser power and beam uniformity testing.
Specifications
|
Model |
JY-MRT |
|
Target Plate Size |
5000x3000mm |
|
Reflectivity |
90% |
|
Wavelength |
940nm |
|
Reflection Accuracy |
±1% |
|
Coating Material |
Lambert RefTarget Coating |
|
Coating Thickness |
>0.2mm |
|
Flatness |
<1mm |
|
Uniformity |
>99% |
|
Substrate |
Honeycomb Aluminum Panel |
|
Thickness |
20mm |
|
Other Specifications |
Customizable |
|
Warranty |
One year (excluding consumables and human-induced damage) |
*The final right of interpretation of this technical specification belongs to the manufacturer.
Contact customer service to get detailed information and a personalized plan
Phone: 400-1800-685
Email: info@gzjygd.com